Treatment method of blister machine after water immersion.
After the flood, if your blister machine is unfortunately flooded, please refer to the following correct handling method to minimize the loss. A professional engineer from Hongyouxing Company writes the following content. for reference only! The treatment method after the blister machine is immersed in water: Electrical part (particularly important) ① Disconnect the power supply, and after confirming all the following steps, the power can be turned on again under the guidance of professionals! Disconnect all power supplies, hang a sign prohibiting closing operation on the main gate, and do not work on the blister machine until the power supply is disconnected. ②Check if water enters the PLC main board and touch screen. If water enters the PLC main board and touch screen, the internal battery needs to be removed as soon as possible. Otherwise, individual components are still energized, worsening the damage of damp components.